YN Shockproof Pressure Gauge

Trademark: RX
Origin: China
Customization:
Diamond Member Since 2010

Suppliers with verified business licenses

Trading Company

Basic Info.

HS Code
9026209000
Production Capacity
10000 PCS/Month

Product Description

YN Shockproof Pressure Gauge
The gauge is suitable for use in vibration and shock environment and is able to withstand pulsation of medium, striking and sudden unloading, while maintaining its reliability. It's designed for use in mechanical, petrol, chemical, mining, purification, power generation industries.

Specification:
Model Structure Style Accuracy % Scale range
MPa
YN-50Z No edge at axial direction ± 2.5 0~0.16; 0~0.25; 0~0.4; 0~0.6; 0~1.0
0~1.6; 0~2.5; 0~4; 0~6; 0~10;
0~16; 0~25; 0~40; 0~60
YN-60 No edge at radial direction
YN-60T With the back part at radial direction
YN-60Z No edge at axial direction
YN-60ZQ With the fore part at axial direction
YN-100 No edge at radial direction ± 1.6 -0.1~0; -0.1~0.06; -0.1~0.15;
-0.1~0.3; -0.1~0.5; -0.1~0.9
-0.1~1.5; -0.1~2.4;
0~0.16; 0~0.25; 0~0.4; 0~0.6; 0~1.0; 0~1.6
0~2.5; 0~4.0; 0~6.0; 0~10; 0~16
0~25; 0~40; 0~60
YN-100T With the back part at radial direction
YN-100Z No edge at axial direction
YN-100ZQ With the fore part at axial direction
YN-150 No edge at radial direction
YN-150T With the back part at radial direction
YN-150Z No edge at axial direction
YN-150ZQ With the fore part at axial direction
Note: According to the necessary, it has the fore rectangle part at axial direction
Operational temperature: -5º C~55º C; -25º C~55º C
Operational environments must have vibration frequency less than 25Hz and amplitude less than 1mm.
Design: Q/320211 DGH01-2003

Dimension:

Model Dimension mm
A B C D d d0 M
YN-50Z 29 24 0 50 / / 14X1.5
YN-60 31 32 14 60 / /
YN-60T 31 32 15 75 3.4
YN-60Z 30 32 0 / /
YN-60ZQ 30 32 0 75 3.4
YN-100 44 45 18 100 / / 20X1.5
YN-100T 44 46 19 118 5.5
YN-100Z 43 45 34 / /
YN-100ZQ 43 45 44 118 5.5
YN-150 50 47 19 149 / / 20X1.5
YN-150T 50 48 20 165 5.5
YN-150Z 51 47 55 / /
YN-150ZQ 51 47 55 165 5.5
Note: According to the necessary, the thread can be on order

Ordering:
Please puncture the rubber stopper with a needle to equalize the pressure inside the instrument cavity with the atmosphere before using gauge. That can avoid to environmental temperature affecting instrument indicator precision.
The operational environment should not have corrosive gas.
Name/Model/Scale range/Connection size

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now